SERVICE

Our basic motor rebuilding service includes
  • diagnostics, bearing replacement, cleaning, meg check, amp check,
    proper break-in procedure to full rpm.
  • Fast turn around.  In most cases 1 -2 days.

Our stator re-winding service includes
  • Upgrade to high temp inverter duty, spike resistant wire.
  • Available for EL-3 and EL-4 motors and NID motors.
HOME               CMS              MOTORS               RAF                CONTACT US
High Efficiency 2 HP Atomizer Motor by NID, Inc.

NID, Inc. is pleased to now offer our own high efficiency 2 HP atomizer motor for the OSB industry.  The HE-2 is a specially
designed motor that is the result of several years of research, development, and testing. It utilizes cutting edge technology
and components that have resulted in a motor that is over 25% more efficient than the standard EL-4 motor.  
This means
our motor runs much cooler and requires far less cooling-air while having more power than conventional atomizer motors.






  • Significantly cooler operating temps
  • Uses 500 watts less energy
  • Requires only 15 PSI cooling air
  • More power
  • Longer lasting
  • Many design improvements
  • Universal fit
  • Competitively priced
  • Full Warranty

  • Contact us for more info and pricing
Coil Atomizer Motor Modifications, Parts and Service

NID offers an extensive selection of parts and service for your EL-3 & EL-4
OEM atomizer motors.
Including:
  • Front and Rear Bearing Housings
  • EL-3 Motor Modification
  • Stator Winding Service
  • Motor Rebuild Service and Diagnostics
Tests were performed on a new Coil EL-4
motor and our HE-2 motor under identical  
maximum (extreme) load conditions, using 2.5
GPM water at 200 Hz. / 12,000 rpm.

No Load Amp Draw, 200 Hz:
  • HE-2 = 2.4 amp
  • EL-4 = 3.8 amp

Max Load Amp Draw, 200 Hz:
  • HE-2 = 3.9 amp
  • EL-4 = 5.4 amp

Max Load Operating Temperature (Fahrenheit)
  • HE-2 = 166 F. at 15 PSI
  • EL-4 = 197 F. at 30 PSI

The HE-2 uses about 500 watts less energy to
perform the same work and runs much cooler
with only 15 psi air pressure.
Model  HE-2
For nearly 20 years we have been rebuilding, rewinding, and modifying EL-3 and EL-4 atomizer motors for mills throughout the U.S
and Canada.  We're very familiar with the temperature related problems associated with these motors as well as other various design
issues.   Our new motor addresses these issues with a complete re-design including improved rotor and stator technology and
materials resulting in the most efficient, reliable atomizer motor in the industry.

We've also included our following design modifications that have proven to add to the performance, reliability and service
convenience in the most demanding applications of the 24/7 blending environment...
A built-in bar clamp slot prevents twisting
in the housing and shearing of wires.
Longer flats on the motor shaft end
for improved durability and grip with
wrench.
A built-in radial extraction groove in front
and rear bearing housing aids in
disassembly
The HE-2  motor universally retrofits all
standard atomizer housings, with a case
that is only 5/8” longer than the EL-4 and
EL-3 motor.  Shaft length and size is
normal. Bearings are normal.
Maximum Load Amp Draw